Pipeline Level Sensor
Pipeline Level Sensor

Applicable pipe diameter:  Φ6-13mm outside diameter

Applicable tube:  Transparent tube with wall thickness less than 1mm

Output mode:  NPN output/PNP output

Setting mode:  key self-learning

Output mode:  NPN.NO/NC


FGU-G613 series
https://item.taobao.com/item.htm?spm=a1z10.5-c-s.w4002-21983907666.10.73483c8bPjcdfq&id=601746321023
  • Characteristics
  • Specifications
  • Size
  • Wire
  • Download

Photoelectric principle, not easily affected by the measured medium;

Self-learning light-sensitive environment by pressing the key, simple and convenient operation;

No mechanical moving parts, high reliability;

Small size, can be installed at will;

Compliance with safety regulations, RoHS standard requirements requirements



Detection PrincipleNon contact photoelectric detection
 Model numberFGU-G613NFGU-G613P
Output type NPN open collector output PNP open collector output
Applicable pipeline materialTransparent/semi transparent catheter
Applicable pipeline outer diameterOuter diameter ø6-13mm
Applicable pipeline wall thicknessWall thickness<1mm
Supply voltage DC12-24±10% ripple wave(p-p)under 5%
 Operating mode ON when blocking light ON when entering light Switching method
 Detected object Liquid in the conduit (if the liquid is highly viscous or has suspended matter, it may not be detected)
 Action indicator light Red status indicator; green status indicator
 Consumption current Average value 30mA or less, maximum value 80mA or less
 Light sourceGaAs infrared light-emitting diode (940nm)
 Ambient illumination Incandescent light - sunlight: 3000 Lux each or less
 Ambient temperature Working: -10--+55 degree Celsius

 Storage: -25--65% Celsius (icing, condensation)

 Ambient humidity When working:5-85%RH When storing:5-95%RH(condensation)
 Vibration (Durable) 10-500Hz  Single amplitude1.0mm
 Impact (Durability) 500m/s2 X,Y,Z 3 times in each direction
 Protective structure IEC specification IP50
 Control output Load power supply voltage DC12-24V, load current below 100mA;

Off power supply 0.5mA or less; residual voltage 0.8V or less (at 100mA load current)

Residual voltage 0.4V or less (at 40mA load current)

 Housing materialPolycarbonate
 Product size 25*16*17.2(length X width X hight)
 Connection mode Lead wire lead line (standard wire length 2m)



Pipeline Level Sensor

Pipeline Level Sensor

FGU-G613说明书
FGU-G613说明书

Do you need help and service?

Full range of product types and wide applicability

We continuously study professional technology to accelerate the localization process of industrial sensors

Scale up across multiple industries, with over a thousand cumulative deployment cases

We look forward to your contact