Laser displacement sensor
Laser displacement sensor

Measurement range: 25-600mm, multiple ranges available for selection

4-digit LED digital display with built-in controller

Analog current and voltage switchable output

Repetitive accuracy up to 10 µ m

Compact size, suitable for installation in various environments



Series: FSD22 switching value+analog output
https://item.taobao.com/item.htm?spm=a1z10.5-c-s.w4002-21983907666.16.214121e7cOtQO2&id=607095577825
  • Characteristics
  • Specifications
  • Size
  • Wire
  • Download

Small volume, small light points;

High detection accuracy and ultra high performance;

Simultaneously equipped with dual outputs of switching and analog quantities;

Multiple detection mode functions can be suitable for more applications;

The top design has a super high output indicator light, which is more intuitive;

Clear and bright Nixie tube display screen, more display end;

Thin film button, easy and convenient to operate and set;

Aluminum alloy shell, sturdy and durable.


TypeMeasurement
center 30mm type
Measurement
center 50mm type
Measurement
center 100mm type
Measurement
center 200mm type
Measurement
center 400mm type
Part numberAnalog+NPN outputFSD22-30N-UIFSD22-50N-UIFSD22-100N-UIFSD22-200N-UIFSD22-400N-UI
Analog+PNP outputFSD22-30P-UIFSD22-50P-UIFSD22-100P-UIFSD22-200P-UIFSD22-400P-UI
Measurement center distance30mm50mm100mm200mm400mm
Measurement range±5mm±15mm±35mm±80mm±200mm
Beam diameter (Note 3)Approx. ø50μmApprox. ø70μmApprox. ø120μmApprox. ø300μmApprox. ø500μm
Repeatability10μm30μm100μm200μm300μm (measurement distance 200 to 400mm)
800μm (measurement distance 400 to 600mm)
Linearity±0.3%F.S.±0.3%F.S.±0.3%F.S. (measurement distance 200 to 400mm)
±0.4%F.S. (measurement distance 400 to 600mm)
Temperature characteristic0.03%F.S./°C
Light sourceRed semiconductor laser Class 2 [JIS / IEC / GB / FDA (Note 2)]
Max. output: 1mW, Emission peak wavelength: 655nm
Supply voltage12 to 24V DC ±10%, Ripple P-P 10% or less
Power consumption40mA or less (at 24V DC supply voltage), 65mA or less (at 12V DC supply voltage)
Control outputControl output
   NPN open-collector transistor
       •Maximum sink current: 50mA
       •Applied voltage: 30V DC or less
                       (Between control output to 0V)
       •Residual voltage: 1.5V or less
                                   (At 50mA sink current)
       •Leakage current: 0.1 mA or less

   PNP open-collector transistor
   •Maximum source current: 50mA
   •Applied voltage: 30V DC or less
               (Between control output to +V)
   •Residual voltage: 1.5V or less
                        (At 50mA source current)
    •Leakage current: 0.1 mA or less
Output operationSwitchable either Light-ON or Dark-ON
Short-circuit protectionIncorporated (Auto reset type)
Analog outputAnalog voltage output•Output range: 0 to +5V (at alarm: +5.2V)
•Output impedance: 100Ω
Analog current output•Output range: 4 to 20mA (at alarm: 0mA)
•Load impedance: 300Ω or less
Response timeSwitchable between 1.5ms / 5ms / 10ms
External input
  NPN non-contact input
    •Input conditions
      Invalid: +8 to +V DC or Open
      Valid: 0 to +1.2V DC
    •Input impedance: Approx. 10kΩ

   PNP non-contact input
     •Input conditions
      Invalid: 0 to +0.6V DC or Open
      Valid: +4 to +V DC
     •Input impedance: Approx. 10kΩ
ProtectionIP67 (IEC)
Degree of pollution2
Ambient temperature-10 to +45°C (No dew condensation or icing allowed), Storage: -20 to +60°C
Ambient humidity35 to 85% RH, Storage: 35 to 85% RH
Ambient illuminanceIncandescent lamp: Acceptance surface illuminance 3,000ℓx or less
Operating altitude2,000m or less
Cable0.2mm2 5-core composite cable, 2m long
MaterialEnclosure: Aluminum die-cast, Front cover: Acrylic
Weight approx. 85g (including cable)
Applicable standardEMC Directive Compliance, FDA Standard, UL Recognition
Notes:





 1) Supply voltage: 24V DC, ambient temperature: +20°C, response time: 10ms, and analog output value of measurement center distance are   used for unspecified measurement conditions. The subject is white ceramics.        
 2) This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard.         
 3) This is the size in the measurement center distance. These values were defined by using 1/e2 (approx. 13.5%) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.


激光位移传感器

激光位移传感器

FSD22说明书
FSD22说明书

Do you need help and service?

Full range of product types and wide applicability

We continuously study professional technology to accelerate the localization process of industrial sensors

Scale up across multiple industries, with over a thousand cumulative deployment cases

We look forward to your contact