CCD wire diameter measurement sensor
CCD wire diameter measurement sensor

Installation spacing: 0~500mm

Measuring range: Width mode 10mm;

                             Edge mode ±5mm

Minimum detection object: 0.2mm

Linearity accuracy: ±0.28% F.S.

CCD wire diameter measurement series for workpiece inner and outer diameter compliance detection sensor

CCD detection method, stable detection, high accuracy

Output mode: with switch and RS485 communication (support ModBus protocol)



Model number:FLM-50-RS485
https://item.taobao.com/item.htm?spm=a1z10.5-c-s.w4002-21983907666.24.340521e7WY19Gg&id=665299718339
  • Characteristics
  • Specifications
  • Size
  • Wire
  • Download

Micron-level measurement accuracy and fast response;

Uniform light output point, accurate detection;

Intuitive digital display, convenient operation;

Strong anti-interference, stable work;

Small size, less space for track installation;

Standard M3 screw design, easy to install.



CCD线径测量传感器

Induction head specification parameters
Model numberFLM-50-RS485
Measuring rangeWidth mode: 10mm; Edge mode: ± 5mm
Mounting pitch0...500mm
Smallest detection objectionΦ0.5mm(setting distance:500mm)
Light sourceRed semiconductor laser; laser class: Class 1
Light spot14*12mm
Supply voltage12...24VDC
Pressure drop<2.5V
Linearity accuracy±0.28%F.S.
Repetition accuracy10μm(setting distance:100mm) 15μm(setting distance:500mm)
SizeThrowing light: 55*32*23mm; receiving light: 55*32*23mm
Temperature drift±0.02%F.S./℃(6mm plug gauge)
Indicator lamp (emission)Optical axis calibration indicator: green LED; power indicator: green LED
Indicator light (receive)Optical axis calibration indicator: green LED; position display: dual bar LED (red and green)
Ambient light resistanceIncandescent lamp:< 3,000lux
Protection levelIP50
Ambient temperature-10...+45℃( No frosting)
Ambient Humidity35...85%RH(No frosting)
MaterialHousing: Aluminum
Connection methodPVC cabble

Remark:

① When the installation distance is 100mm, the light is blocked at a distance of 50mm from the receiver. The error margin to the ideal straight line.

②When the light is half blocked at the middle of the installation distance. The average number of times is set to 16 and sampling is performed for 30 seconds.

(iii) The variation of the measured data when the light is blocked by a 6 mm metal plug gauge at a distance of 50 mm from the receiver at a mounting distance of 100 mm, and the temperature varies from 20 to 50°C.

CCD线径测量传感器

Controller Specification
Supply voltage12...24VDC
Current consumption≤900mA(Including transmitter, receiver)
Display resolution 1 μm
Display range-99.999 ~+99.999
Display typeDouble-digit 7-segment display; upper and lower levels: red, 6 digits
Response time2ms
Output 1NPN/PNP,NO./NC. settable
Output 2 RS485 output or analog output
Ambient temperature -10 ~ +45° C(No freezing)
Ambient Humidity35...85%RH(No condensation)
Enclosure Aluminum
InstallationGuide rail installation



CCD wire diameter measurement sensor

BN12-24V
BUGND
OGInput1
GNInput2
WH485A
BK485B
PKInput3
GYInput4
RDHI output
PLGO output
YLLO output


CCD线径测量传感器-说明书